A marine cable produced in our own factory that combines power/signal conductors and pneumatic tubes, transmitting power, signal and air together.


Product Overview
The hybrid composite cable is a marine cable produced in our own factory that combines power/signal conductors and pneumatic air tubes in a single cable. Three 1.5 mm² bare copper conductors (48×0.20 stranded, resistance < 13.3 Ω/km, compliant with IEC 60228) are stranded together with one or two polyamide air tubes (8 mm OD / 6 mm ID), wrapped with non‑woven tape and sheathed in PVC. The outer diameter is 18 to 20 mm, the rated voltage 250 V and the operating temperature -20 to +70 °C (static), and the cable is flame‑retardant to IEC 60332‑1. It is suitable for marine and industrial installations where power/signal and air supply must be transmitted together.
Technical Specifications
| Conductors | 3 × 1.5 mm² bare copper (48 × 0.20 stranded) |
|---|---|
| Conductor resistance | < 13.3 Ω/km (IEC 60228) |
| Air tubes | 1 or 2 polyamide tubes, 8 mm OD / 6 mm ID |
| Construction | Non‑woven tape + PVC outer sheath |
| Outer diameter | 18 to 20 mm |
| Rated voltage | 250 V |
| Operating temperature | -20 to +70 °C (static) |
| Flame retardancy | IEC 60332‑1 |
Key Features
- Power, signal and air in one cable for simpler installation
- Flame‑retardant to IEC 60332‑1
- Conductors compliant with IEC 60228
- Produced in our own factory with controlled quality
Applications
Related Solutions
More Products

Electromagnetic Flowmeter
Based on Faraday's law of electromagnetic induction, delivering high accuracy and outstanding cost‑effectiveness for conductive liquids.
View details
Twin‑Rotor Positive Displacement Flowmeter
A positive displacement meter in which two precision helical rotors mesh at the same speed, dividing the fluid into equal volumes for counting, with accuracy up to 0.1%.
View details
Coriolis Mass Flowmeter
Twin parallel measuring tubes oscillate at resonance and mass flow is measured directly from the phase difference, together with density and temperature.
View details
Turbine Flowmeter
A flanged turbine flowmeter that measures by average flow velocity on the Woltmann impeller principle, suited to low- and medium‑viscosity liquids.
View details